Weigh the collected weight (taking into account the empty weight of the collecting vessel).
u
Enter the weight under the Calibrated quantity menu entry.
u
Press OK.
The new value is saved in the machine control unit.
The Flow factor calculation menu is displayed.
The flow factor must be between 0.4 and 1.9.
u
Set the flow factor.
In order to apply the newly calculated flow factor, press the Confirm flow factor button.
To confirm the previously saved flow factor, press the ESC key.
The flow factor is saved.
The “Approach drop point” alarm message is displayed.
CAUTION!
Risk of injury due to automatic adjustment of the drop point
When the Start/Stop function key is pressed, the drop point is automatically moved to the preset
value by an electrical actuator (Speedservo). This may cause injury.
▶
Before pressing the Start/Stop key, ensure that nobody is present in the hazard zone of the
machine.
▶
Acknowledge the “Approach drop point” alarm message by pressing Start/Stop.
4.4.6 Disc type
For optimal empty run measurement, check the correct input in the Fertiliser settings menu.
• The entries in the Spreading disc and Normal disc speed or PTO menu items must
correspond to the actual settings of your machine.
The mounted spreading disc type has a default factory setting. If you have mounted different
spreading discs on your machine, you must enter the correct type.
u
Access the menu Fertiliser settings > Spreading disc.
u
Activate the spreading disc type in the selection list.
The Fertiliser settings window is displayed with the new spreading disc type.