No. Message in display Meaning and possible cause
17 Error by settingdrop point The drop point adjustment cannot reach the
specified target value.
Fault, for instance with the power supply
No position feedback
18 Error by settingdrop point The drop point adjustment cannot reach the
specified target value.
Blockage
No position feedback
Calibration test
19 Defect by settingdrop point The drop point adjustment cannot reach the
specified target value.
No position feedback
20 Error at LIN busparticipant: Communication problem
Defective cable
Loose plug connector
21 Spreader overloaded! For weighing spreader only: The mineral
fertilizer spreader is overloaded.
Too much fertilizer in the hopper
22 Unknown conditionFunction-Stop Communication problem with terminal
Possible software error
23 Error by setting TELIMAT The TELIMAT adjustment cannot reach the
specified target value.
Blockage
No position feedback
24 Defect by setting TELIMAT Defective TELIMAT actuator
25 Activate disc start.Confirm with ENTER
26 Discs started upwithout activation Defective or manually switched hydraulics
valve
27 Discs started upwithout activation Defective or manually switched hydraulics
valve
28 Disc could not start upproperly.Deactivate disc
start.
Spreading discs do not rotate.
Blockage
No position feedback
6. Alarm messages and possible causes