No. Message in display Meaning and possible cause
29 The agitator motor isoverloaded. The agitator is blocked.
Blockage
Defective connection
30 The discs shall be activatedbefore opening
themetering sliders.
Correct software operation
Start spreading discs
Open metering slides
31 Idle measurement is necessaryfor EMC
calculation.
Alarm message before the idle measurement
Activate spreading disc start.
32 Externally controlledparts can be moved.Risk
ofinjury through squeezingand shearing! -
Direct ALL persons out of the dangerzone -
Read the instruction manualConfirm with
ENTER
If the machine control unit is activated,
components may move unexpectedly.
Follow the displayed instructions only if all
risks have been eliminated.
33 Stop the discsand close the metering sliders You may only switch to the System / Test menu
area if the spreading operation has been
deactivated.
Stop spreading discs.
Close the metering slide.
45 Error at M-EMC sensors.EMC control
deactivated!
The sensor has stopped sending signals.
Cable breakage
Defective sensor
46 Spreading speed error.Observe spreading
speedof 450..650 rpm!
The PTO speed is outside the range for the
M EMC function.
47 Left dosing error,hopper empty,outflow blocked!
Hopper empty
Outlet blocked
48 Right dosing error,hopper empty,outflow
blocked!
Hopper empty
Outlet blocked
49 Idle meas. implausible.EMC control
deactivated!
Defective sensor
Defective transmission
50 Idle meas. impossible.EMC control deactivated! PTO speed not permanently stable
6. Alarm messages and possible causes