No. Message in display Meaning and possible cause
29 The agitator motor isoverloaded. The agitator is blocked.
• Blockage
• Defective connection
30 The discs shall be activatedbefore opening
themetering sliders.
Correct software operation
• Start spreading discs
• Open metering slides
31 Idle measurement is necessaryfor EMC
calculation.
Alarm message before the idle measurement
• Activate spreading disc start.
32 Externally controlledparts can be moved.Risk
ofinjury through squeezingand shearing! -
Direct ALL persons out of the dangerzone -
Read the instruction manualConfirm with
ENTER
If the machine control unit is activated,
components may move unexpectedly.
• Follow the displayed instructions only if all
risks have been eliminated.
33 Stop the discsand close the metering sliders You may only switch to the System / Test menu
area if the spreading operation has been
deactivated.
• Stop spreading discs.
• Close the metering slide.
45 Error at M-EMC sensors.EMC control
deactivated!
The sensor has stopped sending signals.
• Cable breakage
• Defective sensor
46 Spreading speed error.Observe spreading
speedof 450..650 rpm!
The PTO speed is outside the range for the
M EMC function.
47 Left dosing error,hopper empty,outflow blocked!
• Hopper empty
• Outlet blocked
48 Right dosing error,hopper empty,outflow
blocked!
• Hopper empty
• Outlet blocked
49 Idle meas. implausible.EMC control
deactivated!
• Defective sensor
• Defective transmission
50 Idle meas. impossible.EMC control deactivated! PTO speed not permanently stable
6. Alarm messages and possible causes
96
5902180-h-gb- AXIS EMC ISOBUS