No. Message in display Meaning and possible cause
52 Error at hopper cover The position of the hopper cover could not
be reached.
Blockage
Defective actuator
53 Defect at hopper cover The hopper cover actuator cannot reach the
target value for the movement.
Blockage
Defective actuator
57 Error at hopper cover The hopper cover actuator cannot reach the
target value for the movement.
Blockage
No position feedback
71 Impossible to reachdisc speed The spreading disc speed is not within the 5 %
target range.
Problem with oil supply
Proportional valve spring is jammed.
72 Error at SpreadLight Power supply is too high; the operating lights
will be switched off.
73 Error at SpreadLight Overload
74 Defect at SpreadLight Connection error
Defective cable
Loose plug connector
82 Type of machine modified.Spreading error
possible.New configuration required!
The operating modes cannot be combined with
certain machine types
u
Restart the machine control unit when
changing machine type.
u
Implement machine settings.
u
Load fertilizer chart for the machine type.
88 Error at disc speed sensor The spreading disc RPM could not be
determined
Cable breakage
Defective sensor
6. Alarm messages and possible causes