Loading...
CAUTION!
Risk of injury due to moving machine parts
During the tests, machine parts may move automatically.
Before carrying out the tests, ensure that nobody is present in the danger zone of the
machine.
You can open and close the metering sliders with the up/down arrows.
Example: LIN bus
u
Access the menu System / Test > Test/diagnosis.
u
Select the LIN bus menu item.
The display shows the status of the actuators/sensors.
Fig. 25: System / Test; Example: Test/diagnosis
[1] Status display
[2] Start self-test
[3] Connected equipment
Linbus participant status notification
The devices indicate various conditions:
0 = OK; no equipment error
2 = blockage
4 = overload