3. AIR PUMP TIMING ADJUSTMENT
Purpose:
To ensure that the paper exit pawl air pump produces a jet of air
at the proper time.
1. Remove the rear cover.
2. Set the drum in the home position.
3. Confirm that the mark [A] on the pump drive gear [B] is located directly
over the gear shaft [C].
4. If incorrect, remove the support plate [D] (5 screws) and reposition the
gear.
5. Rotate the drum to the home position and repeat the procedure.
[B]
[C]
[B]
[A]
[D]
C224 5-8 SM