Service Call Conditions
D017/D018/D019/D020/D084/D085 3-10 SM Appendix
353 B ID sensor LED current error
Error occurred during automatic
adjustment of Vsg:
Vsg output did not attain 4V,
even with PWM = 1023
(maximum current for LED)
Vsg output was greater than 4V,
even with PWM=1 (no current
for the LED)
ID sensor dirty or defective
ID sensor harness disconnected,
or connector damaged
IOB defective
High voltage power supply board
(power pack) defective
Scanning system or image
creation system malfunction
354 B ID sensor adjustment timeout error
Error occurred during
automatic adjustment of
Vsg. Vsg could not be
adjusted to 4.0V ±0.2V
within the prescribed time.
ID sensor dirty or defective
ID sensor harness disconnected, or
connector damaged
BCU defective
High voltage power supply board (power
pack) defective
355 C
ID sensor error
For more details about the
cause of the problem,
please refer to SC350 to
354 above.
ID sensor dirty or defective
ID sensor harness disconnected, or
connector damaged
BCU defective
High voltage power supply board (power
pack) defective

Table of Contents