Service Call Conditions
SM Appendix 3-9 D017/D018/D019/D020/D084/D085
Appendix:
Service Call
Conditions
350 B
ID sensor calibration – Error 1
One of the following conditions occurred when the ID sensor pattern was
calibrated during printing:
Vsp > 2.5V
Vsg < 2.5V
Vsp = 0V
Vsg = 0V
ID sensor defective or dirty
ID sensor harness disconnected or connector is damaged
BCU defective
Scanning system or image creation system malfunction
High voltage power supply board (power pack) defective
351 B
ID sensor calibration – Error 2
The following conditions occurred simultaneously when the ID sensor
pattern was calibrated during printing:
Vsg = 5V
PWM = 0 (LED current drop)
ID sensor dirty or defective
ID sensor harness disconnected, or connector damaged
BCU board defective
High voltage power supply board (power pack) defective