Service Call Conditions
D017/D018/D019/D020/D084/D085 3-8 SM Appendix
230 D FGATE ON error
The FGATE signal did not assert within the
prescribed time. (The BCU generates the
FGATE signal and sends it to the LD unit
when the registration sensor switches on.)
BCU, Controller board
harness loose or broken
BCU defective
Controller board defective
231 D FGATE OFF error
The FGATE signal did not go off within the
prescribed time. (The BCU generates the
FGATE signal and sends it to the LD unit
when the registration sensor switches on.)
240 LD error
The IPU detected a
problem at the LD unit.
LD unit harness broken, defective
BCU harness broken defective
LD unit defective
BCU defective
302 D
Charge level output error
The PWM output level was detected
higher than 50% after 10 consecutive
samplings.
HVPS (High Voltage Power
Supply) board harness loose,
broken.
PCU connection loose or
broken