System SP Tables-1
SM Appendix 4-5 D017/D018/D019/D020/D084/D085
Appendix:
Service
Program
Mode
1109*
Fusing Nip Band Check
Checks the fusing nip band.
1 Execution
2
Idling Rotation Time
[0 to 120 / 60 / 1 sec]
Specifies the fusing rotation time before executing SP1109-001.
3
Pre-Idling Time
[5 to 30 / 10 / 1 sec]
Specifies the time that the paper stops in the fusing unit for measuring the
nip.
1159
Fusing Jam Detection
Disables or enables the consecutive jam error for the fusing unit.
[0 to 1/0/1 Step]
When set to "1" (on) this SC code is issued after the 3rd consecutive jam in
the fusing unit.
1902*
AC Frequency Display DFU
Displays the AC frequency for fusing temperature control.
[0 to 1/0/1 Step]
Used to check the measured number of interrupts for the zero cross signal.
Measured time interval is 500 ms with 5 interrupts per 2 mms:
10 ms x 50 = 500