System SP Tables-1
D017/D018/D019/D020/D084/D085 4-4 SM Appendix
9 After Warming-up - Time
In this machine, fusing temperature is kept
10°C higher than the normal temperature
for a short while after the machine warms
up. This SP selects the length of time that
this temperature is used. See Detailed
Section Descriptions – Fusing for more
details.
[0 to 180 / 60 / 1s/step]
10 Wait Temp: Center Minus
11 Wait Temp: Ends Minus
1106 Fusing Temperature Display
1 Roller Center
Displays the fusing temperature for the center or
both ends of the hot roller.
2 Roller Ends
3
In the Machine at Power
On
Displays the temperature in the machine at
power on.
This temperature is monitored by the thermistor
on the SBCU board.
1108*
Fusing Soft Start Adj: Cycle
Selects whether the fusing temperature control cycle is 1 or 3 seconds.
If this is "1 (3 s)", the power supply fluctuation caused by the fusing lamp
turning on is less often.
[0 = 1 s / 1 = 2 s]
Default: 0 = N. America, Taiwan, 1 = Europe/Asia