System SP Tables-5
D017/D018/D019/D020/D084/D085 4-82 SM Appendix
31
Scanner
Determines whether certification is required before a user can use the scan
applications.
[0 to 1/0/1]
0: On
1: Off
41
Printer
Determines whether certification is required before a user can use the
printer applications.
[0 to 1/0/1]
0: On
1: Off
51 SDK1
[0 or 1/ 0 / 1] 0: ON. 1: OFF
Determines whether certification is required before a user
can use the SDK application.
61 SDK2
71 SDK3
5481
Authentication Error Code
These SP codes determine how the authentication failures are displayed.
1
System Log Disp
Determines whether an error code appears in the system log after a user
authentication failure occurs.
[0 to 1/0/1]
0: Off
1: On
2
Panel Disp
Determines whether an error code appears on the operation panel after a
user authentication failure occurs.
[0 to 1/1/1]
1: On
0: Off