System SP Tables-5
SM Appendix 4-83 D017/D018/D019/D020/D084/D085
Appendix:
Service
Program
Mode
5490
MF Keycard Japan Only
Sets up operation of the machine with a keycard.
[0 to 1/0/1]
0: Disabled. Cancels operation if no code is input.
1: Enabled. Allows operation if another code is input and decrements the
counter once for use of the entered code.
5501* PM Alarm
1
PM Alarm Interval
Sets the PM interval.
The value stored in this SP is used when the value of SP5501 2 is "1".
[0 to 255 / 0 / 1 k copies/step]
2
Original Count Alarm DFU
Selects whether the PM alarm for the number of scans is enabled or not.
If this is "1", the PM alarm function is enabled.
[0 = No / 1 = Yes]
5504*
Jam Alarm Japan Only
Sets the alarm to sound for the specified jam level (document misfeeds are
not included). RSS use only
[0 to 3 / 3 / 1 step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5505*
Error Alarm
Sets the error alarm level. Japan only DFU
[0 to 255 / 50 / 100 copies per step]