System SP Tables-5
SM Appendix 4-95 D017/D018/D019/D020/D084/D085
Appendix:
Service
Program
Mode
007
SSL Disable
Uses or does not use the RCG certification by SSL when calling the RCG.
[0 to 1 / 0 / 1 /step]
0: Uses the RCG certification
1: Does no use the RCG certification
008
RCG Connect Timeout
Specifies the connect timeout interval when calling the RCG.
[1 to 90 / 10 / 1 second /step]
009
RCG Write Timeout
Specifies the write timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
010
RCG Read Timeout
Specifies the read timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
011
Port 80 Enable
Enables/disables access via port 80 to the SOAP method.
[0 or 1 / 0 / – ]
0: Disabled, 1: Enabled
013
RFU (Remote Frimware Update) Timing
Selects the RFU timing.
[0 or 1 / 1 / – ]
0: RFU is executed whenever update request is received.
1: RFU is executed only when the machine is in the sleep mode.
021
RCG – C Registed
This SP displays the Embedded RC Gate installation end flag.
0: Installation not completed
1: Installation completed