SP2-xxx: Drum-1
SM 5-27 G179
Service
Tables
3: Horizontal Line (1 dot)
4: Horizontal Line (2 dot)
5: Grid Vertical Line
6: Grid Horizontal Line
7: Grid pattern small
8: Grid Pattern Large
9: Argyle Pattern Small
10: Argyle Pattern Large
11: Independent pattern (1 dot)
12: Independent Pattern (2 dot)
16: Hound’s Tooth Check (Horizontal)
17: Black Band (Horizontal)
18: Black band ( Vertical)
19: Checker Flag Pattern
20: Grayscale (Vertical Margin)
21: Grayscale (Horizontal Margin)
22: Two Beam Density Pattern
23: Full Dot Pattern
24:All white Pattern
[0 to 15 / 15 /1 ]
002 Density
Set the density of the test pattern which is output in
SP2109-001. This SP is not used for the Grayscale
patterns.
2201*
Dev. Bias Adj.
Development Bias
[200 to 700 / 560V / 10V ]
001
Adjusts the development bias for printing.
Use as a temporary measure to correct faint printouts from an aging drum.
ID Sensor Pattern
[200 to 700 / 400V / 10V ]
002
Adjusts the development bias for the ID sensor pattern for VSP
Forced Toner Supply
2207
Forces the toner bottle to supply toner at 1-second intervals for up to 30
seconds. To start, press the "EXECUTE" button.
Toner Supply Mode
[0: Sensor, 1: pixel ]
2208*
Selects the toner mode.
If you select "1", SP2-209-002 should be set to its default value. Use image