SP2-xxx: Drum-2
SM 5-33 G179
Service
Tables
TD Sen. Ini. Set Initialization
2801*
Performs the TD sensor initial setting and allows the service technician to
enter the lot number of the developer. (The lot number is embossed on the
edge of the developer package.) This SP mode controls the voltage applied
to the TD sensor to make the TD sensor output about 3.0 V. Press
“EXECUTE” to start. After finishing this, the TD sensor output voltage is
displayed.
Use this mode only after installing the machine, changing the TD sensor, or
adding new developer.
TD Sen. Man. Set.
2802*
Allows you to adjust the TD sensor output manually for the following.
VTS
[1 to 5 / 4.78 / 0.01vol ]
001
Adjusts the TD sensor output (VT).
Change this value after replacing the development unit with another one
that already contains toner. For example, when using a development unit
from another machine for test purposes. To adjust VT, use a similar
procedure as for SP2-220.
VTMAX
[1 to 5 / 4.78 / 0.01vol ]
002
Adjusts the maximum value for SP2802 1.
VTMIN
[1 to 5 / 1 / 0.01vol ]
003
Adjusts the minimum value for SP2802 1.
Process Setting (Not used)
2805*
Performs the developer initialization. Press “Execute” to start. This SP
should be performed after doing SP2801 at installation and after replacing
the drum.
2810 Paper Setting