SP2-xxx: Drum-2
G179 5-34 SM
Initializes the LD power setting. This SP should be done after replacing the
drum.
2912* Tr. Rev. Rotation
Interval
[0 to 10 / 3 / 1 ]
002
Sets the reverse time of the transfer/development motor after the end of a
job.
2914*
Process Control Setting
C-alpha
[0 to 400 / 150 / 10vol ]
001
Adjusts the charge roller voltage used when paper with a small width is fed
from the by-pass tray. The paper width below which the correction starts
depends on the value of SP2-309-1.
Use this SP when an image problem (such as white spots at the center of
black dots or breaks in thin black lines) occurs when paper with a small
width is fed from the by-pass feed tray.
C-beta
[0 to 400 / 0 / 10vol ]
002
Adjusts the charge roller voltage used when paper with a small width is fed
from the by-pass tray. The paper width below which the correction starts
depends on the value of SP2-309-2.
Use this SP when an image problem (see 2-914-1) occurs when paper with
a small width is fed from the by-pass feed tray.
B-gamma
[0 to 300 / 200 / 10vol ]
003
Adjusts the development bias used when paper with a small width is fed
from the by-pass tray. The paper width below which the correction starts
depends on the value of SP2-309-1.
Use this SP when an image problem (see 2-914-1) occurs when paper with
a small width is fed from the by-pass feed tray.
004 B-delta
[0 to 300 / 50 / 10vol ]