SP2-xxx: Drum-3
G179 5-36 SM
5.8 SP2-XXX: DRUM-3
Toner Overflow Sens
[0 = OFF, 1= ON]
2960*
Selects whether or not the toner overflow sensor is activated.
2974* Image Density
Adj. Mode
[1 to 5 / 3 / 1 ]
001
Adjusts image density. Changing this setting adjusts development bias and
ID sensor output voltage that in turn raises or lowers image density.
Near End Setting
Detection Time
[0 to 2000 / 0 / 10 sec ]
2975*
Sets a time for toner supply motor rotation for issuing the toner near end
warning on the operation panel. The time may need to be shorter for
customers who run especially large print jobs (working at night, for example)
to ensure earlier warning of the toner near end condition so toner out does
not interrupt a long job.
Bottle Motor Time
2976*
Displays the total ON time of the toner supply motor, calculated from when
the toner bottle was replaced. Use this to check that the toner end count
(SP2975) is working properly.
When SP2975 is set to any value other than “0”, this value is displayed
when it matches the setting of SP2975. When SP2975 is set to “0”, SP2976
is disabled. SP2976 is automatically set to zero by toner end recovery.)
[0 to 7,000,000 / 0 / 1 msec]
Toner End Status
2977*
Indicates the toner near end or end condition.