SP5-xxx: Mode-1
G179 5-42 SM
5.11 SP5-XXX: MODE-1
All Indicators On
5001
Lights the LCD and all LEDs on the operation panel to demonstrate that
they are operating properly.
[OFF/ON]
mm/inch Selection
0: Europe/Asia (mm)
1: North America (inch)
5024*
Selects the unit of measurement.
After selection, turn the main power switch off and on.
Status Lamp Mode
5037*
Determines whether the status lamp on the operation panel operates or not.
If a customer finds the flashing of this lamp disturbing, use this SP to switch
it off.
[0 to 1 / 1 / 1]
0: Lamp operation off
1: Lamp operation on
Display IP Address
5055*
Display or does not display the IP address on the LCD.
[0 to 1 / 0 / 1]
0: OFF, 1: ON
5056* Coverage Counter
Display or does not display the coverage counter on the LCD.
[0 to 1 / 0 / 1]
0: Not displayed, 1: Displayed