SP5-xxx: Mode-1
SM 5-51 G179
Service
Tables
Sets the number of sheets to clear the error alarm counter.
The error alarm counter counts "1" when any SC is detected. However, the
error alarm counter decreases by "1" when an SC is not detected during a
set number of printed sheets (for example, default 5000 (C1b) or 10000
(C1c) sheets). The error alarm occurs when the SC error alarm counter
reaches "5".
[0 to 255 / 100 / 100 printouts / step]
5507* Supply Alarm
001 Paper Size
Switches the control call on/off for the paper
supply. (DFU)
0: Off, 1: On
0: No alarm.
1: Sets the alarm to sound for the specified
number transfer sheets for each paper size (A3,
A4, B4, B5, DLT, LG, LT, HLT)
002 Staple
Switches the control call on/off for the stapler
installed in the finisher. (DFU)
0: Off, 1: On
0: No alarm
1: Alarm goes off for every 1K of staples used.
003 Toner
Switches the control call on/off for the toner end.
(DFU)
0: Off, 1: On
If you select “1” the alarm will sound when the
machine detects toner end.
010 Maintenance Kit A
Switches the PM alarm call to @Remote on/off for
the Maintenance-A Kit (DFU).
0: Off, 1: On
011 Maintenance Kit B
Switches the control call to @Remote on/off for
the Maintenance-B Kit. (DFU)
0: Off, 1: On