SP5-xxx: Mode-3
SM 5-57 G179
Service
Tables
5.13 SP5-XXX: MODE-3
5816* NRS Function
I/F Setting
001
Turns the remote diagnostics off and on.
[0 to 2 / 2 / 1]
0: Remote diagnostics OFF.
1: Serial (CSS) remote diagnostics ON.
2: @Remote diagnostics. ON
CE Call
002
Lets the customer engineer start or end the remote machine check with CSS
or @Remote; to do this, push the center report key
Function Flag
003
Enables or disables the remote service function.
[0 to 1 / 0 / 1]
0: Disables remote diagnosis over the network.
1: Enables remote diagnosis over the network.
SSL Disable
007
Controls if RCG (Remote Communication Gate) confirmation is done by SSL
during an RCG send for the @Remote over a network interface.
[0 to 1 / 0 / 1]
0: Yes. SSL not used.
1: No. SSL used.
RCG Connect Timeout
008
Sets the length of time (seconds) for the time-out when the RCG (Remote
Communication Gate) connects during a call via the @Remote network.
[1 to 90 / 30 / 1 sec.]
009 RCG Write Timeout