SP5-xxx: Mode-3
SM 5-63 G179
Service
Tables
CERT: ExpTime
094
Displays the end time of the period for which the current @Remote
certification is enabled.
Manual Polling
200
No information is available at this time.
Instl: Condition
Displays a number that indicates the status of the @Remote service device.
0
Neither the registered device by the external nor embedded RCG device
is set.
1
The embedded RCG device is being set. Only Box registration is
completed. In this status, this unit cannot answer a polling request from
the external RCG.
2
The embedded RCG device is set. In this status, the external RCG unit
cannot answer a polling request.
3
The registered device by the external RCG is being set. In this status the
embedded RCG device cannot be set.
201
4 The registered module by the external RCG has not started.
Instl: ID#
202
Allows entry of the number of the request needed for the embedded RCG.
Instl: Reference
203
Executes the inquiry request to the @Remote Gate Way URL.
Instl: Ref Rslt
Displays a number that indicates the result of the inquiry executed with
SP5816-203.
0 Succeeded
204
1 Inquiry number error