4.Service Tables
80
7
Communication Switch 0C - Not used (do not change the settings)
Communication Switch 0D (SP No. 1-104-014)
No Function Comments
0-
7
The available memory threshold, below
which ringing detection (and therefore
reception into memory) is disabled
00 to FF (Hex), unit = 4 kbytes
(e.g., 06(H) = 24 kbytes)
One page is about 24 kbytes.
The machine refers to this setting before each fax reception. If
the amount of remaining memory is below this threshold, the
machine cannot receive any fax messages.
If this setting is kept at 0, the machine will detect ringing
signals and go into receive mode even if there is no memory
available. This will result in communication failure.
Communication Switch 0E (SP No. 1-104-015)
No Function Comments
0-
7
Minimum interval between automatic
dialing attempts
06 to FF (Hex), unit = 2 s
(e.g., 06(H) = 12 s)
This value is the minimum time that the machine waits before it
dials the next destination.
Communication Switch 0F – Not used (do not change the settings.)
Communication Switch 10 (SP No. 1-104-017)
No Function Comments
0-7 Memory transmission: Maximum number of dialing attempts to the same
destination
01 – FE (Hex)
times
Communication Switch 11 – Not used (do not change the settings.)
Communication Switch 12 (SP No. 1-104-019)
No Function Comments
0-7 Memory transmission: Interval between dialing attempts to the same destination 01 – FF (Hex) minutes
Communication Switch 13 – Not used (do not change the settings.)