4.Service Tables
81
Communication Switch 14 (SP No. 1-104-021)
No Function Comments
0 Inch-to-mm conversion during
transmission
0: Disabled, 1: Enabled
0: In immediate transmission, data scanned in inch format are
transmitted without conversion.
In memory transmission, data stored in the SAF memory in mm
format are transmitted without conversion.
Note: When storing the scanned data into SAF memory, the fax unit
always converts the data into mm format.
1: The machine converts the scanned data or stored data in the SAF
memory to the format which was specified in the set-up protocol
(DIS/NSF) before transmission.
1-
5
Not used Do not change the factory settings.
6-
7
Available unit of resolution in
which fax messages are received
For the best performance, do not change the factory settings.
The setting determined by these bits is informed to the transmitting
terminal in the pre-message protocol exchange (in the DIS/NSF
frames).
Bit 7 Bit 6 Unit
0 0 mm
0 1 inch
1 0 mm and inch
1 1 Not used
Communication Switch 15Not used (do not change the settings)
Communication Switch 16Not used (do not change the settings)
Communication Switch 17 (SP No. 1-104-024)
No Function Comments
0 SEP reception
0: Disabled
1: Enabled
0: Polling transmission to another maker's machine using the SEP
(Selective Polling) signal is disabled.
1 SUB reception
0: Disabled
1: Enabled
0: Confidential reception to another maker's machine using the
SUB (Sub-address) signal is disabled.
2 PWD reception
0: Disabled
1: Enabled
0: Disables features that require PWD (Password) signal
reception.
3-
4
Not used Do not change the settings.
5 PSTN dial-in routing setting 1: The machine sets multiple PSTN dial-in numbers in the PSTN