Mainframe Installation
47
Value Meaning Solution/ Workaround
11 Already registered -
12 Parameter error -
20 Dial-up authentication error * These errors occur only in the modems that support
@Remote.
21 Answer tone detection error
22 Carrier detection error
23 Invalid setting value (modem)
24 Low power supply current
25 unplugged modem
26 Busy line
5. Make sure that the screen displays the Location Information with SP5-816-205 only when it has been input
at the Center GUI.
6. Click [EXECUTE] to execute the registration with SP5-816-206.
7. Check the registration result with SP5-816-207.
Value Meaning Solution/ Workaround
0 Succeeded -
1 Request number error Check the request number again.
2 Already registered Check the registration status.
3 Communication error (proxy enabled) Check the network condition.
4 Communication error (proxy
disabled)
Check the network condition.
5 Proxy error (Authentication error) Check Proxy user name and password.
8 Other error See "SP5-816-208 Error Codes" below this.
9 Request number confirmation
executing
Processing… Please wait.
11 Already registered -
12 Parameter error -
20 Dial-up authentication error * These errors occur only in the modems that support
@Remote.
21 Answer tone detection error
22 Carrier detection error
23 Invalid setting value (modem)
24 Low power supply current
25 unplugged modem
26 Busy line
8. Exit the SP mode.
SP5-816-208 Error Codes
Caused by Operation Error, Incorrect Setting
Code Meaning Solution/ Workaround