3.SP Mode Tables 
55 
2-
143-
005 
TM/ID Sensor Check  Minimum: Front  ENG*  [ 0 to 5.5 / 0 / 0.01V ] 
2-
143-
006 
TM/ID Sensor Check  Minimum: Center  ENG*  [ 0 to 5.5 / 0 / 0.01V ] 
2-
143-
007 
TM/ID Sensor Check  Minimum: Rear  ENG*  [ 0 to 5.5 / 0 / 0.01V ] 
2-
146-
005 
TM-Sensor Check Result  Number of Edge 
Detection:Front 
ENG*  [ 0 to 16 / 0 / 1 ] 
2-
146-
006 
TM-Sensor Check Result  Number of Edge 
Detection:Center 
ENG*  [ 0 to 16 / 0 / 1 ] 
2-
146-
007 
TM-Sensor Check Result  Number of Edge 
Detection:Rear 
ENG*  [ 0 to 16 / 0 / 1 ] 
2-
154-
002 
Shad. Correct Setting  Front End Area: Bk: LD1  ENG*  [ 50 to 150 / 100 / 
0.1% ] 
2-
154-
003 
Shad. Correct Setting  Front End Area: Bk: LD2  ENG*  [ 50 to 150 / 100 / 
0.1% ] 
2-
154-
005 
Shad. Correct Setting  Front End Area: Ma: LD1  ENG*  [ 50 to 150 / 100 / 
0.1% ] 
2-
154-
006 
Shad. Correct Setting  Front End Area: Ma: LD2  ENG*  [ 50 to 150 / 100 / 
0.1% ] 
2-
154-
007 
Shad. Correct Setting  Front End Area: Cy: LD1  ENG*  [ 50 to 150 / 100 / 
0.1% ] 
2-
154-
008 
Shad. Correct Setting  Front End Area: Cy: LD2  ENG*  [ 50 to 150 / 100 / 
0.1% ] 
2-
154-
009 
Shad. Correct Setting  Front End Area: Ye: LD1  ENG*  [ 50 to 150 / 100 / 
0.1% ]