3.SP Mode Tables
380
No. Part Name SP Name SP No. Reading
0 1
- - PP:T1T2:SC Detection 5-803-045 SC detected No SC
- - PP:CB:SC Detection 5-803-044 SC detected No SC
- - BiCU Version Detection 5-803-056 - -
- - Key Counter 1: Set Detection 5-803-047 Set Not set
- - Key Counter 2: Set Detection 5-803-048 Not set Set
- - Keycard: Set Detection 5-803-049 Set Not set
Output Check
No. Part Name SP Name SP
No.
Remark
1 Fusing fan Fusing Fan: High
Speed
5-
804-
009
Fusing Fan: Low
Speed
5-
804-
010
2 LD unit fan Laser Unit Fan: High
Speed
5-
804-
011
Laser Unit Fan: Low
Speed
5-
804-
012
3 PCDU
cooling
duct fan
PCDU Cooling Fan:
High Speed
5-
804-
015
PCDU Cooling Fan:
Low Speed
5-
804-
016
4 PSU fan PSU Fan: High
Speed
5-
804-
013
PSU Fan: Low Speed 5-
804-
014
- - PP:Charge DC:Y 5-
804-
044
Do not turn ON these SPs with the PCDU installed.
If you turn ON with the PCDU installed, an electric
current continues to flow in a particular place of the