Technical Bulletin PAGE: 6/39
Model: Aries-P1.5/C1.5 Date: 15-Jun-11 No.: RM077037
Step A-1. “D4477579: SHEET: SHIFT TRAY: MIDDLE”
The Mylar is attached to 2 separate sheets divided by a slit. Peel off only the ‘Top’ part.
Step A-2. Keep in mind the corner indicated ‘A’ as a reference point, and attach the ‘Top’ part of the Mylar to
the tray so that all edges of the Mylar are positioned 2mm inside the edges of the tray.
Step A-3. Peel off the ‘Bottom’ sheet and slowly attach the Mylar outward from the center. Make sure that
the edge of the far side also does not protrude against the line.
Step A-4. Finally, rub the Mylar entirely for complete attachment.
NOTE
1. Attach the Mylar slowly to avoid air-bubbles between the Mylar and the
tray.
2. The Mylar must be attached in one attempt.
Do NOT peel off and reattach the Mylar to correct the position.
The position should be well adjusted before actually attaching the Mylar.
2mm
2mm
A
The Mylar MUST be positioned
correctly in this area.
Slit
Top
Bottom