Technical Bulletin PAGE: 3/5
Reissued: 09-Jan-14
Modified Points or Symptom Corrected
- Early web cleaning indication has been fixed
- fuser unit PM counter is corresponding to several fusing unit to prevent
fusing belt from wearing away
- Countermeasure for 2 output checks, waste toner could clog and disable
the function of the toner collection coil, which could result in breakage of
the gear rotating the waste toner transport coil, and toner leakage.
- Following adjustable range has been changed in Web Image Monitor
Erase Margin Adj Leading Edge
Erase Margin Adj Trailing Edge
Minimum setting 0.0 --> -6.0
Following firmware need to be upgraded together
Bugs in menu items in Custom Paper Setting Advanced Setting are fixed.
Item Menu No. 03 "Pickup Assist Setting"
Item Menu No. 15 "Paper Transfer Feed Speed Adjustment"
Bug which has been fixed
Even the No. 03 "Pickup Assist Setting"was set as OFF, inside the machie,
"Pickup Assist Setting" was set to auto setting; therefore, depending on Paper
weight and Paper Size, "Pickup Assist Setting"
was activated.
Even the No 15 "Paper Transfer Feed Spped Adjustment" was set as
0.0, PTR was not moving at the correct speed
Apply Condition for Creo Controller
Please use Creo Controller Ver 1.003:16 or older.