Technical Bulletin PAGE: 3/11
Reissued:04-Apr-14
Model: Aries-P1.5/C1.5, AG-P1/C1
Date: 01-Oct-12
No.: RM077075c
NOTE: Make sure the Dust, Development and Ozone filters are replaced at the
prescribed PM intervals.
Clogged filters will decrease the air current from the fans and prevent
complete removal of corona products.
Dust filter: Replace at 400K intervals.
Development filter: Clean with a vacuum at 400K intervals.
Ozone filters: [A] Large, [B] Medium, [C] Small: Replace at 1,200K invervals.