Technical Bulletin PAGE: 13/15
Reissued:16-Oct-12
Model: Aries-C1.5 (D095) / Aries-P1/.5(M077) Date: 8-Nov-2012 No.: RM077077b
Solution caused by toner degradation
Procedure 1: Toner Refresh Amount Adjustment
Modify the following SP to increase the toner refresh amount.
1-1. Make sure that the current value in SP3-701-009 (Max Pattern Length) is “25”.
1-2. Modify the SP values indicated in red in the following table.
NO
TE 1: Make sure the same value is applied for C, M, and Y.
NOTE 2: Toner yield will decrease for devices with an average coverage of 4% or lower.
3-701-009
Toner Refresh Mode: Max Pattern Length
[0 to 25 / 25 / 1 mm]
Toner Refresh Mode DFU
Default
K: 5%
Color: 2.5%
Modified
5%
3.8%
3-701-001 Image Area: K 12.5 12.5
3-701-002 Image Area: C 6.0
9.4
3-701-003 Image Area: M 6.0
9.4
3-701-004 Image Area: Y 6.0
9.4
3-701-005 Image Area Thresh: K 12.5 12.5
3-701-006 Image Area Thresh: C 6.0
9.4
3-701-007 Image Area Thresh: M 6.0
9.4
3-701-008 Image Area Thresh: Y 6.0
9.4