Technical Bulletin PAGE: 5/5
Reissued:05-Mar-14
Model: Aries-P1.5/C1.5
Date: 01-Mar-13
No.: RM077086c
Table 3
Cause
No.
Symptom
Action
Note
High friction
between the
drum and
cleaning blade
1
SC39x after power-on
Power Off-On
Symptom occurs only
immediately after
machine power-on.
2
Stopper seal on the
cleaning unit is twisted
and/or loose.
Correct the sealing. If
the seal cannot be
corrected, replace the
cleaning unit.
Loose seal causes
higher friction.
3
SC39x immediately
after installing a new
drum
Lubricate the drum.
Insufficient lubricant
causes higher friction.
Compressed
developer
between the
dev roller and
drum as a result
of system
forced
termination
4
SC39x following a
Jam037
Manually rotate the
dev roller (clockwise
viewed from front) to
remove the
compressed
developer.
Jam037 (fusing unit) is
a system forced
termination status;
highly likely to cause
compressed developer
between the
components.
5
SC39x as a result of
opening the front
doors before a
complete machine
stop
Same as above
No front door open
while machine is
working.
Excess
developer in the
development
unit
6
Excess developer on
dev roller
Completely remove
the developer from the
development unit and
replace with brand
new developer.
Incomplete
developer
replacement causes
the developer to
increase in the unit.
See RM077072 for
details on how to
completely clear out
the developer from
the unit.
Toner blocking
in the drum
cleaning unit
7
Toner clogged
between the brush
roller and toner
collection coil
Replace the old drum
cleaning unit
(M0773601) with the
new unit (M0773602)
See RTB
RM077102.