T
echnical
B
ulletin PAGE: 3/6
Model:
Aries-P1.5/C1.5, AG-P1/C1, AGL-P1/C1
Date:
29-Nov-13
No.:
RM077099
Solution to drum scratch problems
Drum scratches caused by cleaning components
z Replace with a new drum.
Drum scratches caused by insufficient lubrication
z Replace with a new drum. Make sure to lubricate the new drum before installing.
Drum scratches caused by narrow PG
z A narrow PG could be caused by an incompletely fastened drum knob. Refer to the
following RTB for the proper drum knob fastening procedure.
¾ RG178128d (pages 5~9)
z Check that the drum is properly installed.
¾ RG178128d (page 4)
z Remove the toner adhered to the surface of the development roller.
¾ RG178128d
z Do #208 “Execute Toner Refreshing” in the Adjustment Settings for Skilled Operators
Menu.
NOTE: The developer DOES NOT have to be replaced.
If the DG (doctor gap) is clogged with toner, remove the clogged toner with a piece of
paper, then do #208 “Execute Toner Refreshing” again.
Toner adhesion
on dev roller