Technical Bulletin PAGE: 7/44
Model: Aries-P1.5/C1.5 Date: 17-Feb-11 No.: RM077018
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Harness loose or disconnected
Waste toner transport motor 1 defective
Blocking in the toner collection tube to the waste toner bottle.
1. Check the harness connection.
2. Replace the waste toner transport motor 1.
3. If necessary, unblock the toner transport path.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Waste toner transport motor 2: Lock error
The machine detects an error of the waste toner transport motor
2 while it is rotating.
Harness loose or disconnected
Blocking in the toner collection tube to the waste toner bottle.
Waste toner transport motor 2 defective
486 D
1. Check the harness connection.
2. Replace the waste toner transport motor 2.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Waste toner transport motor 2 sensor error
The machine detects an error of the waste toner transport motor
2.
Blocking in the toner collection tube to the waste toner bottle.
Waste toner transport motor 2 defective
Waste toner transport motor 2 sensor defective
489 D
1. Check or replace the waster toner bottle.
2. Replace the waster toner transport motor 2
3. Replace the waster toner transport motor 2 sensor
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Charge unit cleaning motor K error
The machine detects a short or open signal of the coil in the
charge unit cleaning motor K (black).
Harness from IOB 1 to this motor short, broken or
disconnected
Coil in this motor short or open
490
-001
D
1. Check the harness connection.
2. Replace the harness.
3. Replace the charge corona unit cleaning motor.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Charge unit cleaning motor C error 490
-002
D
The machine detects a short or open signal of the coil in the
charge unit cleaning motor C (cyan).