Technical Bulletin PAGE: 9/44
Model: Aries-P1.5/C1.5 Date: 17-Feb-11 No.: RM077018
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Drum motor Y error
The machine detects a short or open signal of the coil in the drum
motor Y (yellow).
Possible causes are same as SC490-005.
490
-008
D
Countermeasures are same as SC490-005.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
IITB black lift motor error
The machine detects a short or open signal of the coil in the ITB
black motor.
ITB drawer incorrectly set
Harness from IOB 2 to this motor short, broken or
disconnected
Coil in this motor short or open
490
-009
D
1. Check if the ITB drawer is correctly set.
2. Check the harness connection.
3. Replace the harness.
4. Replace the ITB black lift motor.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
ITB color lift motor error
The machine detects a short or open signal of the coil in the ITB
color motor.
ITB drawer incorrectly set
Harness from IOB 2 to this motor short, broken or
disconnected
Coil in this motor short or open
490
-010
D
1. Check if the ITB drawer is correctly set.
2. Check the harness connection.
3. Replace the harness.
4. Replace the ITB color lift motor.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Belt centering motor error
The machine detects a short or open signal of the coil in the belt
centering motor.
ITB drawer incorrectly set
Harness from IOB 2 to this motor short, broken or
disconnected
Coil in this motor short or open
490
-011
D
1. Check if the ITB drawer is correctly set.
2. Check the harness connection.
3. Replace the harness.
4. Replace the belt centering motor.