Technical Bulletin PAGE: 35/75
Reissued:21-Apr-14
Model: Aries-P1.5/C1.5
Date: 10-Mar-14
No.: RM077107b
If the above is not accepted by the customer due to extra power consumption, ask for
customer approval and install the external power supply unit.
This part is excerpted from RTB RM077075b.
Part information
Please add the following part to your Aries-P1.5/C1.5 and Aegis-P1/C1 parts catalog.
Part number
Description
Page
Index
Note
M0772500
Service Parts: Power Supply Unit
87
17
Add
For
ProC900
M0772500
Service Parts: Power Supply Unit
93
20
Add
For
ProC901
AC power cable included - NA 125V
- EU 250V
Notes on Using the External PSU
When using the external PSU, confirm that the LED is lit before turning on the main
power. If the main power is turned on while the LED is not lit, this will result in SC.
LED will not light up if the breaker switch is turned off or if the timer is set to off.
Refer to the last section of this document for instructions on how to switch supply
means between Pro C900 / Pro C901 and the external PSU.