Technical Bulletin PAGE: 35/75
Reissued:21-Apr-14
If the above is not accepted by the customer due to extra power consumption, ask for
customer approval and install the external power supply unit.
This part is excerpted from RTB RM077075b.
Part information
Please add the following part to your Aries-P1.5/C1.5 and Aegis-P1/C1 parts catalog.
Service Parts: Power Supply Unit
Service Parts: Power Supply Unit
AC power cable included - NA 125V
- EU 250V
Notes on Using the External PSU
When using the external PSU, confirm that the LED is lit before turning on the main
power. If the main power is turned on while the LED is not lit, this will result in SC.
LED will not light up if the breaker switch is turned off or if the timer is set to off.
Refer to the last section of this document for instructions on how to switch supply
means between Pro C900 / Pro C901 and the external PSU.
Please refer the RTB RM077075b for External PSU installation in detail.
M0772500 Service Part: Power Supply Unit