Technical Bulletin PAGE: 13/44
Model: Aries-P1.5/C1.5 Date: 17-Feb-11 No.: RM077018
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
ITB scratched or broken
Dust on the ITB
New Laser unit installed
Process control execution incorrect
1. Execute the manual process control with SP3820-001.
2. Clean or replace the ITB.
3. Replace the laser unit YM or CK.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Temperature/Humidity sensor K error
The output of the temperature sensor was not within the
prescribed range (0.5V to 4.2V) for 3 minutes.
Temperature and humidity sensor harness disconnected,
loose, defective
Temperature and humidity sensor defective
497 C
1. Check the connector and harness.
2. Replace the temperature/humidity sensor K below the black
PCDU.