Technical Bulletin PAGE: 62/75
Reissued:21-Apr-14
2-9. Hold the dev unit as shown in the photo below and turn the Mag roller half to 1 full
rotation to convey the developer onto the Mag roller.
2-10. Repeat steps 2-5 to 2-9 until the amount of loose developer on the Mag roller
appears as in the photo below.
NOTE
After removing older developer, the development unit should weigh no more than
7,900 grams. If a scale is available on-site, you may want to weigh the dev unit to
ensure correct developer removal.
Loose developer will continue to appear on the surface of the Mag roller if you keep
rotating the Mag roller. Do not keep rotating the Mag roller, but complete the
procedure as soon as you confirm that the remaining amount of loose developer is as
shown in the photo above.