Technical Bulletin PAGE: 14/35
Reissued: 6-Jun-15
Model: Aries-C1.5/P1.5 (D095/M077)
3.3.3 Procedure
1. Insert the NICE SD card into the service slot on the controller box.
2. Press ‘Test Print: FR Adjust’ on the main menu screen.
NOTE: This test chart can only be printed on A3 or DLT paper.
75%/60% (75U/60L) and 30%/15% (30U/15L) halftone charts will be printed in
CMYK (total of 8 sheets).
3. Place the 75U/60L and 30U/15L charts of the affected color on the contact glass
and press ‘Scan: FR Adjustment’ to scan these charts.
(See 2.3 ‘Common procedure for scanning test charts’ for the correct scanning
procedure.)