Technical Bulletin PAGE: 19/35
Reissued: 6-Jun-15
Model: Aries-C1.5/P1.5 (D095/M077)
Date: 17-Jun-14
No.: RM077114a
3.4.2 Procedure
1. Insert the NICE SD card into the SD card slot on the controller box and wait for
the NICE main menu screen to appear.
2. Place the NICE Calibration Chart (p/n: D0749671) on the contact glass and press
‘Scan: Banding’ to scan the calibration chart.
NOTE: See section 2.2 ‘Common procedure for scanning test charts’ for the
correct scanning procedure.
3. Then, on the operation panel, press ‘Test Print: 75%&CSC’ to print out the 75%
charts.
NOTE: 75% charts (Bk,C,M,Y,R,G,B) and CSC chart (similar pattern as
calibration chart) will be printed out.
i)
i)