Technical Bulletin PAGE: 24/35
Reissued: 6-Jun-15
Model: Aries-C1.5/P1.5 (D095/M077)
Date: 17-Jun-14
No.: RM077114a
13. Wait for the Banding Analyzer window to appear. Select the product model from
Menu Group Products.
14. Click Run, then select and save the dat file created in step 12.
15. Excel will launch automatically after the calculation completes to display the
parts/units that should be inspected to resolve bands in the order of
effectiveness.
Higher the bar, higher the necessity of the inspection.
NOTE: When the Banding Analyzer does not automatically start, please select
from Start All Programs NICE Banding Analyzer.