Setting Items
Default
Value
Max.
Value
Min.
Value
Step Unit
[Tray 1] 0.000 0.500 -0.500 0.025 %
[Tray 2]
[2-Tray LCIT: Tray 3]
[2-Tray LCIT: Tray 4]
[2-Tray LCIT: Tray 5]
[2-Tray LCIT: Tray 6]
[2-Tray LCIT: Tray 7]
[2-Tray LCIT: Tray 8]
[Bypass Tray]
[Extended Option Tray]
0107 [Image Magnification: Across Feed: Side 1]/0108 [Image Magnification:
Across Feed: Side 2]
Adjust the vertical image scaling to print on Side 1/2 of the paper according to the paper expansion or
shrinkage.
• Depending on the setup, the print side (Side 1/Side 2) with respect to the delivery and paper feed
directions may vary. For details, see page 11 "Paper Feed Direction of Printed Copies (Side 1/
Side 2)"
• This setting is not effective for paper fed from paper trays with custom paper presets. For such
paper, the value specified in [Across Feed] in [Image Magnification Result: Side 1]/[Image
Magnification Result: Side 2] in 1101 [Image Position] in "Advanced Settings" takes precedence.
2. Details of Menu Items in Adjustment Settings for Operators
26