[Machine: Maintenance]
0501 [Execute Cleaning Initial Setting for PCU]
Execute after replacement of photoconductor cleaning unit and drum. Do not open the left and right
front covers during the operation. The control panel shows information during the operation.
• If it is necessary to execute this for all colors, execute it in the order of [CMY] and [Black].
Setting Items Remarks
[CMY] Press [Execute].
[Black]
[Cyan]
[Magenta]
[Yellow]
Setting Item
Default
Value
Max.
Value
Min.
Value
Step Unit
[No. of Pattern Repeats] 6 16 0 1 times
0502 [Wind Fuser Cleaning Unit at Replacement]
Wind Fusing Cleaning Web
Setting Item Remarks
[Execute] Press [Execute].
0503 [Reset Parts Counter]
Reset the counter value of replacement part after the replacement. Refer to "Replacement Manual" for
the procedure of part replacement.