0515 [Fusing Belt Smoothing Setting (Set by User)]
Set interval and duration when [Auto Execute: Set by User] is selected at [Auto Exe: Belt Scratches] in
[Fusing Belt Smoothing Setting] for Custom Paper.
Setting Items
Default
Value
Max.
Value
Min.
Value
Step Unit
[No. of Sheets per Interval] 500.00 600000.
00
0 0.01 page
[Execution Time] 150 360 10 sec
0516 [Manage Multiple Fusing Units by Counter]
Display the counter of Fusing Unit parts
Setting Item Values Default Value
[Fuser Unit No.] [Unit 1]
[Unit 2]
[Unit 3]
[Unit 4]
[Unit 1]
2. Details of Menu Items in Adjustment Settings for Operators