:FETCh:DISChargingTime?
:MEASure:DISChargingTime?
Syntax :FETCh:DISChargingTime?
:MEASure:DISChargingTime?
Description
Reads the discharge time of the battery.
Return
Format
The query returns a real number.
:FETCh:TIME?
:MEASure:TIME?
Syntax :FETCh:TIME?
:MEASure:TIME?
Description
Reads the integration time of the instrument.
Return
Format
It is the integration time of 10 PLC. It is 200, and its unit is ms.
:FETCh:WAVedata?
:MEASure:WAVedata?
Syntax :FETCh:WAVedata?
:MEASure:WAVedata?
Description Reads the data points (400 data points) in the data cache area in the waveform display
interface.
Return
Format
The query returns 400 consecutive data points.