RIGOL Chapter 2 Command System
2-22 DL3000 Programming Guide
the maximum value of the load's regulated current; and the parameter "DEFault"
indicates querying the default value of the load's regulated current.
Return
Format
The query returns a real number.
Example :SOUR:CURR:LEV:IMM 3 /*Sets the load's regulated current in CC mode to be 3 A.*/
:SOUR:CURR:LEV:IMM? /*Queries the load's regulated current set in CC mode.*/
[:SOURce]:CURRent:RANGe
Syntax [:SOURce]:CURRent:RANGe {<value>|MINimum|MAXimum|DEFault}
[:SOURce]:CURRent:RANGe? [MINimum|MAXimum|DEFault]
Description Sets the current range in CC mode and transient operation mode to be a high range or a
low one.
Queries the current range set in CC mode and transient operation mode.
Remarks The default range is a low range.
In the setting command, the parameter "MINimum" indicates setting a low range; the
parameter "MAXimum" indicates setting a high range; and the parameter "DEFault"
indicates setting the default range.
In the query command, the parameter "MINimum" indicates querying a low range;
the parameter "MAXimum" indicates querying a high range; and the parameter
"DEFault" indicates querying the default range.
Return
Format
The query returns a real number.
Example :SOUR:CURR:RANG 60 /*Sets the current range in CC mode to be 60 A (a high range).*/
:SOUR:CURR:RANG? /*Queries the current range set in CC mode.*/
[:SOURce]:CURRent:SLEW
Syntax [:SOURce]:CURRent:SLEW[:BOTH] {<value>|MINimum|MAXimum|DEFault}
[:SOURce]:CURRent:SLEW[:BOTH]? [MINimum|MAXimum|DEFault]
Description Sets the rising and falling slew rate in CC mode.
Queries the rising and falling rate set in CC mode.
Remarks The rising and falling rate of the load set in CC mode are called the slew rate of the
load in CC mode. Its unit is A/
μs.
In the setting command, the parameter "MINimum" indicates setting the minimum
rate; the parameter "MAXimum" indicates setting the maximum rate; and the
parameter "DEFault" indicates setting the default rate.
In the query command, the parameter "MINimum" indicates querying the minimum
rate; the parameter "MAXimum" indicates querying the maximum rate; and the
parameter "DEFault" indicates querying the default rate.
Return
Format
The query returns a real number.
Example :SOUR:CURR:SLEW:BOTH 0.5 /*Sets the slew rate in CC mode to be 0.5 A/μs.*/
:SOUR:CURR:SLEW:BOTH? /*Queries the slew rate set in CC mode.*/

Table of Contents

Other manuals for Rigol DL3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DL3000 and is the answer not in the manual?

Rigol DL3000 Specifications

General IconGeneral
BrandRigol
ModelDL3000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals