RIGOL
Users Guide for DM3058
2-28
To Measure Sensor
Random Sensor measurement is a new conception being forward to meet users
requirements. By using this particular function, you can connect Pressure Sensor or
Flux Sensor or Temperature Sensor easily. Its principle is that transmit measured
physical quantity to a facile measured one such as Voltage, Resistance and Current
by these steps. First, pre-input the needed data; secondly, transform or modify it
according to the interior arithmetic of Multimeter. Afterward, a measured physical
quantity of Sensor is shown on the screen directly and you can edit or modify its
display unit at will.
DM3058 supports DCV, DCI, and Freq, 2WR, 4WR and Thermocouple TC 6 kinds of
Sensor in all. Meanwhile, there are 10 groups of basic Sensor preset within the
instrument.