Chapter 2 Command System RIGOL
MSO1000Z/DS1000Z Programming Guide 2-161
:TRIGger:POSition?
Syntax
:TRIGger:POSition?
Description
Query the position in the internal memory that corresponds to the waveform trigger
position.
Return
Format
The query returns an integer.
-2 denotes that the instrument is not triggered and there is no trigger position.
-1 denotes the instrument is triggered outside the internal memory; namely, at this
point, users cannot set the instrument to read the data in the internal memory
starting from the trigger position.
An integer that is greater than 0 denotes that the return value is the position in the
internal memory that corresponds to the trigger position.
Example
:TRIGger:POSition? /*The query returns 100*/

Table of Contents

Other manuals for Rigol DS1054Z

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1054Z and is the answer not in the manual?

Rigol DS1054Z Specifications

General IconGeneral
Channels4
Bandwidth50 MHz
Sample Rate1 GSa/s
Memory Depth24 Mpts
Display7 inch TFT LCD (800x480)
Vertical Sensitivity1 mV/div to 10 V/div
Time Base Range5 ns/div to 50 s/div
Vertical Resolution8 bits
Trigger TypesEdge, Pulse, Video, Slope
ConnectivityUSB Host, USB Device, LAN
Input Impedance1 MΩ
Power Supply100-240 VAC, 45-440 Hz