EasyManuals Logo

Rigol DS1054Z Programming Guide

Rigol DS1054Z
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
RIGOL Chapter 2 Command System
2-2 MSO1000Z/DS1000Z Programming Guide
:AUToscale
Syntax
:AUToscale
Description
Enable the waveform auto setting function. The oscilloscope will automatically adjust the
vertical scale, horizontal timebase, and trigger mode according to the input signal to
realize optimum waveform display. This command is equivalent to pressing the AUTO key
at the front panel.
Explanation
Theoretically, waveform auto setting function requires that the frequency of sine is no
lower than 41Hz; the duty cycle should be greater than 1% and the amplitude must
be at least 20mVpp for square (the probe ratio is 1X).
When the pass/fail function is enabled (see the :MASK:ENABle command), if you sent
this command, the oscilloscope will disable the pass/fail function firstly and then
execute the waveform auto setting function.
When the waveform record function is enabled or during the playback of the
recorded waveform, this command is invalid.
:CLEar
Syntax
:CLEar
Description
Clear all the waveforms on the screen. If the oscilloscope is in the RUN state, waveform
will still be displayed. This command is equivalent to pressing the CLEAR key at the front
panel.
Related
Command
:DISPlay:CLEar
:RUN
:STOP
Syntax
:RUN
:STOP
Description
The :RUN command starts the oscilloscope and the :STOP command stops the
oscilloscope. These commands are equivalent to pressing the RUN/STOP key at the
front panel.
Explanation
When the waveform record function is enabled or during the playback of the recorded
waveform, these commands are invalid.

Table of Contents

Other manuals for Rigol DS1054Z

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1054Z and is the answer not in the manual?

Rigol DS1054Z Specifications

General IconGeneral
Channels4
Bandwidth50 MHz
Sample Rate1 GSa/s
Memory Depth24 Mpts
Display7 inch TFT LCD (800x480)
Vertical Sensitivity1 mV/div to 10 V/div
Time Base Range5 ns/div to 50 s/div
Vertical Resolution8 bits
Trigger TypesEdge, Pulse, Video, Slope
ConnectivityUSB Host, USB Device, LAN
Input Impedance1 MΩ
Power Supply100-240 VAC, 45-440 Hz

Related product manuals