09/2016 Page 28 5IN2371 C
Viewing Zones, Defining Partitions, and Setting the Time & Date
You can now view enabled zones (the default of 64 zones, or the total number of
enabled zones which includes any additional zone licenses purchased via the RISCO
Store and activated using HandyApp), select the maximum number of partitions,
and set the time & date.
NOTE: You can opt to define the maximum partitions at a later stage – from the
keypad (during installer programming), or from the Configuration Software.
NOTE: To add additional zone licenses after system initialization, see Viewing &
Updating Zones and Defining Partitions after Initialization, page 29.
Viewing Zones, Defining Partitions, and Setting Time/Date at Initialization
To view enabled zones, define partitions, and set time/date at system
initialization:
1. When prompted, enter the installer code (default is 1111), then press OK ( ).
If you don’t enter the code within 10 seconds, wait a few seconds for the keypad
to restart;
If the panel configuration is Cloud-compatible (IP/GSM module/s are
installed), then CLOUD CONNECTING displays as the panel tries to connect to
the Cloud. If there is trouble connecting, CONNECTION TROUBLE. RETRY?
will display – in this case, check parameters and perform diagnostics (see the
ProSYS Plus Installation and Programming Manual section on Troubleshooting) and
then select Y (yes) to try again to reconnect or press N (no).
-OR-
If the panel configuration is not Cloud-compatible (IP/GSM module/s are not
installed), then 064 ZONES ENABLED displays (the default number of zones).
2. Press ; upon successful Cloud connection, if new zone licenses (above the 64
supplied) have been purchased, they will display. If no new zone licenses were
purchased, the default 064 Zones Enabled displays.
3. Press ; PARTITION QUAN 08 (08—32) displays.
4. Enter the maximum number of partitions you want in the system – the default is
08 (meaning up to 8); but up to 32 can be selected. If you want more than 8
partitions, enter the number. Now press ; ENTER TIME/DATE displays.
5. Enter the time and date, and then press ; BUS DEVICE: 1) AUTOMATIC
displays, indicating you are now in the installer Programming menu, and ready
to perform an Auto Settings scan (see Step 3: Allocating and Configuring Installed